-40%

Webasto AT2000STC 12V diesel full complect + timer multicontrol HD

$ 411.84

Availability: 100 in stock

Description

Webasto Air Top 2000 ST air heaters are designed for:
heating the interior of the vehicle (cab, interior, cargo compartment and cargo)
defrosting the Windows of the cab/interior
when installing additional options – ventilation of the interior of the vehicle.
Air Top 2000 ST heaters are not allowed for heating trucks carrying dangerous goods. The heaters operate independently of the car engine and are connected to the fuel tank and the vehicle's on-Board network. These heaters can be used in vehicles with both air and liquid - cooled engines.
Kit contents (for more information, see the link)
Heater
Control unit (rheostat)
Conrtol unit (timer multicontrol HD)
fuel pump with mounting Bracket
Heater mounting bracket
Silencer on the air intake for combustion
Silencer pipe 1 meter
Fuel tube 7 meters
Wiring harness with fuse box
Relay for switching on the interior stove fan
Package with terminals, fasteners, ties, bolts and nuts, clamps, and other installation elements.
The principle of operation of the air heater Webasto Air Top 2000 ST.
When the heater is turned on, the glow pin is turned on. The fan motor of the heated air and combustion air starts working at 50% power. After 40 seconds, the metering pump is switched on and flame formation begins. For the best start-up result, the metering pump and the combustion air blower start working at different frequencies and speeds. After 95 (petrol) or 110 (diesel) seconds, the glow pin is switched off and the flame sensor monitors the combustion process.Gorenje
During Gorenje, gases generated during the combustion process pass through the heat exchanger. In this case, the heat from them is transmitted through the walls of the heat exchanger to the heating air supplied by the supercharger further to the heated room.
MULTICONTROL HD Features
Number of preheater start-up programs in the weekly timer 3
The accuracy of setting the start time of the heater is up to 1 min.
The duration of the warm-up program is from 10 minutes to 60 minutes.
Manual start of the preheater yes
Manual shutdown of the preheater yes
Vehicle interior ventilation mode (if supported by the preheater) yes
Built-in temperature sensor in the car interior yes
Size (W x D x H) 68mm x 15mm x 48mm
Voltage 12 V-24 V
Maximum current consumption (standby mode) 0.5 mA
Maximum current consumption 17mA-23mA
Weight 21 grams
Operating temperature from -40 C to +75 C
TECHNICAL PARAMETERS
Specifications / modification                           Air Top 2000 STC B                       Air Top 2000 STC D
Certification marks                                                                 ECE-R122 (heating)
ECE-R10 (e/m compatibility)                                                         equipment
type                                                                            Air heater with evaporative burner
Heat output (control range)                                1.0 -2.0 kW                                       0.9 -2.0 kW
Fuel Petrol Diesel
Fuel consumption (±10%)                                  0.1 .. 0.2 kg/h                                  0.1 .. 0.21 kg/h
Control range                                                    (0.14 .. 0.27 l/h)                               (0.12 .. 0.24 l/h)
Rated operating voltage                                            12 V                                              12/24 V
Operating voltage, range                                     10.5–16 V                                  10,5–16 / 21-32 In
Rated power consumption (control range)                                      14-29 W
Permissible ambient temperature:
Heater:
operation                                                                                      -40 to +80°C
storage                                                                                        -40 to +125°C
Fuel pump:
operation                                                                                      -40 to +30°C
storage -40 to +85°C
Controls:
operation                                                                                      -40 to +75°C
storage                                                                                         -40 to +85°C
Temperature range set on the control unit                                    +5 to +35°C
Volume flow of heated air (at 0.5 mbar back pressure)       no more than 78 m3/h
The fan speed                                                                             4750 Rev/min.
The level of CO2 in the exhaust gases at the power output
1 kW                                                                                            5.0 ... 8.0 vol.%
2 kW                                                                                           9.0 ... 12.5 vol.%
dimensions
Dimensions of the main heater Unit length                                  311 ± 2 mm
Width                                                                                            120 ± 1 mm
Height                                                                                           121 ± 1 mm
Weight of the main heater unit                                                         2.6 kg